Keywordsalgorithm;, characterization;, Deconvolution, function, function;, giant, giant-magnetoresistive, Head, heads;, image, image;, imaging;, Interference, interference;, intersymbol, ISI-distorted, ISI-free, magnetic, magnetization, magnetoresistance;, patterns;, readback, removal;, response, signal;, spin-stand, suppression;
Abstract

A novel intersymbol interference (ISI) removal technique based on the "response function" characterization of giant-magnetoresistive heads is presented. It is demonstrated that the ISI-free readback image that corresponds to the actual underlying magnetization patterns can be extracted from the ISI-distorted readback signal through deconvolution. A new image deconvolution algorithm has been implemented, and it has been shown that it effectively removes the ISI distortions.